400W metal halide equivalent LED high bay light
Why use LED lights to replacement metal halide? The energy efficiency means money back in your pocket because you pay
less on your energy bill. Use 150W LED hi bay replacement 400W metal Halide
bulb. To you it means you will be saving money on electricity while saving the
environment.
The factory use 92pcs 400W metal halide
high bay lighting fixture in the work shop, 8hours per day, and operating 26
days per month
Current Lighting
Fixture(400W MH)
|
New LED light (150W LED
high bay)
|
||
Current bulb Wattage
|
460
|
LED light wattage
|
150
|
Number of bulbs
|
92
|
Number of LED lights
|
9
|
Operating hours per day
|
8
|
Operating hours per day
|
8
|
Total Watts per day
|
338560
|
Total Watts per day
|
110400
|
Divided by 1000(KWh)
|
338.56
|
Divided by 1000(Kwh)
|
110.4
|
Operating days per month
|
26
|
Operating days per month
|
26
|
Total kWh cost
|
8802.56
|
Total kWh cost
|
2870.4
|
Current KWh cost
|
$0.19
|
Current KWh cost
|
$0.19
|
Per bulb maintenance & Ballast per
month
|
0.51
|
||
Maintenance & Ballast per month total
|
46.92
|
||
Cost per month to operate bulbs
|
1719.41
|
Cost per month to operate bulbs
|
545.38
|
Cost per month to operate bulbs plus HVAC
|
1977.32
|
||
Total Annual cost to operate
|
23727.81
|
Total Annual cost to operate
|
6544.51
|
Total annual CO2 emissions(Metric Tons)
|
65.64
|
Total annual CO2 emissions(Metric Tons)
|
21.41
|
HVAC loads@15% monthly cost
|
257.91
|
HVAC loads@15% monthly cost
|
44.24
|
Total LED savings monthly
|
1431.94
|
||
Total LED savings annually
|
17183.30
|
||
Total LED savings percentage
|
72.42%
|
||
Total CO2 Emissions Reduction
|
67.39%
|